Mesh repair of a pelvic bone defect caused by a migrated acetabular cup


Malazgirt Z., Tomak Y., Gulman B., Dervisoglu A., Selcuk O.

Hernia, cilt.5, sa.3, ss.153-155, 2001 (Scopus) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 5 Sayı: 3
  • Basım Tarihi: 2001
  • Doi Numarası: 10.1007/s100290100015
  • Dergi Adı: Hernia
  • Derginin Tarandığı İndeksler: Scopus
  • Sayfa Sayıları: ss.153-155
  • Anahtar Kelimeler: Acetabular cup, Hernia repair, Hip prosthesis, Polypropylene mesh
  • Ondokuz Mayıs Üniversitesi Adresli: Evet

Özet

Conventional transacetabular removal of the migrated acetabular cup can be hazardous due to intraoperative injury to iliac vessels. We present a case of a migrated acetabular cup, in which we used a combined preperitoneal and acetabular approach for its removal. With a bimanual approach, the procedure was safer and easier and allowed mesh repair of the pelvic bone defect. The preperitoneal mesh repair is a well-known method for inguinofemoral hernias. However, it has not been used before in the repair of an acetabular defect after removal of a migrated cup.