P-Wave Dispersion and Atrial Electromechanical Delay in Patients with Preeclampsia


Creative Commons License

Inci S., Nar G., Aksan G., Sipahioglu H., Soylu K., Dogan A.

MEDICAL PRINCIPLES AND PRACTICE, cilt.24, sa.6, ss.515-521, 2015 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 24 Sayı: 6
  • Basım Tarihi: 2015
  • Doi Numarası: 10.1159/000435857
  • Dergi Adı: MEDICAL PRINCIPLES AND PRACTICE
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.515-521
  • Anahtar Kelimeler: Atrial electromechanical delay, Intra-atrial conduction time, Iteratrial conduction time, Preeclampsia, Tissue Doppler imaging, STANDARDS COMMITTEE, NON-DIPPER, ECHOCARDIOGRAPHY, RECOMMENDATIONS, QUANTIFICATION, PREDICTION
  • Ondokuz Mayıs Üniversitesi Adresli: Evet

Özet

Objectives: To investigate the duration of atrial electromechanical delay (EMD) and left atrial mechanical function in patients with preeclampsia. Materials and Methods: This study included 26 pregnant women with preeclampsia and 24 age-matched pregnant women without preeclampsia (control group). Atrial electromechanical coupling (PA) and intra-atrial and interatrial EMD were measured using tissue Doppler echocardiography. P-wave dispersion (PWD) was measured via 12-lead electrocardiography. All data were analyzed using SPSS v. 15.0 for Windows (SPSS, Inc., Chicago, Ill., USA). Differences in continuous variables between groups were examined using a nonparametric Mann-Whitney U test. Correlation analysis was performed using Spearman's coefficient of correlation. Categorical values were compared using a. 2 test. Results: PA lateral and PA septal durations were significantly longer in the preeclampsia group than in the control group [74.6 +/- 8.1 vs. 62.3 +/- 5.3 ms (p < 0.001) and 59.7 +/- 5.3 vs. 56.2 +/- 4.9 ms (p = 0.005), respectively]. The duration of interatrial EMD and intra-atrial EMD in the pre-eclampsia group was significantly longer than in the control group [25.4 +/ 4.6 vs. 13.2 +/- 3.9 ms (p < 0.001) and 10.5 +/- 1.9 vs. 7.1 +/- 1.2 ms (p < 0.001), respectively]. PWD was significantly higher in patients with preeclampsia (43.1 +/- 9.1 ms) than in the controls (37.6 +/- 7.9 ms; p = 0.008). There was a significant correlation between PWD and interatrial EMD and intra-atrial EMD [r = 0.46 (p < 0.001) and r = 0.39 (p < 0.001), respectively]. Conclusion: The duration of atrial EMD and PWD was prolonged in patients with preeclampsia. (C) 2015 S. Karger AG, Basel